Construction Site LED Lighting

An advanced low-voltage temporary lighting system. Specification-grade LED performance at 27.5VDC — below the 50V shock-hazard threshold defined by OSHA 1910.333 and NFPA 70E.

Construction Lighting Is Broken. We Fixed It.

Temporary construction lighting hasn’t changed in decades — line-voltage stringers daisy-chained across active job sites, exposed to water, impact, and tool damage. OSHA still lists electrocution among construction’s “Fatal Four.” FLEX SLS 3.0 reclassifies the entire hazard profile.

Construction Lighting Is Broken. We Fixed It.

Electrocution risk

FLEX SLS runs on 27.5VDC — same class as automotive lighting. Effectively zero shock risk, even in wet conditions.

System-level efficiency

Even against line-voltage LED stringers, FLEX wins on architecture: FM2A modules draw just 6W per fixture, and a single centralized FPS550 power supply drives up to 68 modules across 680’ of bus line — with 3kV surge protection built in.

Speed of deployment

Twist-and-lock T-Connectors eliminate splices entirely — no wire nuts, no junction boxes, no conduit. Modules reconfigure on-site as work progresses, and any laborer can do it.

OSHA & code requirements

Operating at 27.5VDC — below the 50V shock-hazard threshold defined by OSHA 1910.333 and NFPA 70E — means no GFCI requirement and no Lock-Out / Tag-Out procedures for repositioning. Backed by ETL Listed listing on the FPS550 power supply.

Project-scale flexibility

One modular system, one part number family, covers everything from a single-room renovation to a 50-story high-rise — add modules and FPS550 supplies as the build expands, then redeploy on the next job.

Worker safety

Construction-grade housings handle drops and impacts; surfaces stay warm, never hot — safe to touch, safe near materials.

FLEX SLS 3.0

Modular Low-Voltage Construction Lighting — an advanced temporary lighting system.

FLEX SLS Logo

FLEX SLS 3.0

Modular Low-Voltage Construction Lighting

FLEX SLS 3.0 modular lighting system

Key Features

27.5VDC low-voltage eliminates electrocution risk
Modules twist-and-lock together without tools
Warm to the touch — safe for workers & materials
Lower per-fixture draw than typical line-voltage LED stringers
Durable construction-grade housing
Daisy-chain from a single power supply
OSHA compliant for temporary construction lighting
Scalable from small interiors to large builds

Applications

High-Rise Construction Commercial Build-Outs Renovation Projects Tunnel Construction Infrastructure Projects

Key Specifications

Operating Voltage 27.5VDC (below 50V shock-hazard threshold)
Module Design Modular, daisy-chainable
Module Lineup FM2A 6W · FM10A 21W · FM30A 50W
Surface Temp Warm to touch (safe for contact)
Connection Twist-and-lock T-Connector (no splicing)
OSHA Fully compliant with temporary lighting requirements
Certification UL, BABA/BAA
Safety First

At 27.5VDC, the FLEX SLS 3.0 operates below the recognized threshold for electrical hazard. Even in direct contact with live conductors in wet conditions, the fixture is designed to reduce line-voltage exposure to negligible levels.

27.5VDC
FLEX SLS
120V+
Traditional

FLEX SLS 3.0 vs. Traditional Temporary Lighting

A direct comparison across the metrics that matter most on active construction sites.

Specification
FLEX SLS 3.0 Clear-Vu Lighting
Line-Voltage LED Stringers Industry Standard
Temporary High-Bays Alternative
Voltage 27.5VDC 120V / 277V 120V / 277V
Electrocution Risk None High High
Power architecture One central 550W supply · 68 modules No driver (line-voltage LED) Driver per fixture
Connection method Twist-and-lock T-Connector (no splice) Spliced strings Hard-wired fixtures
Modularity Full modular Fixed length Individual fixtures
Surface Temp Warm to touch Hot Hot
OSHA Compliance Full Requires GFCI Requires GFCI

Twist. Connect. Illuminate.

The FLEX SLS 3.0 modular system makes construction site lighting as simple as it should be.

1. Twist and Lock

Modules connect with tool-free twist-and-lock T-Connectors. No wire nuts, no junction boxes, no conduit, no splicing. Any laborer can do it.

2. Connect Power

Daisy-chain multiple modules from a single 27.5VDC power supply. Scale from one room to an entire floor in minutes.

3. Illuminate Safely

Full illumination at 27.5VDC. Zero electrocution risk. Warm to the touch. OSHA compliant out of the box. Relocate as the build progresses.

Construction Lighting Documentation

White Paper

FLEX SLS Construction Safety

Safety analysis and performance data for the FLEX SLS 3.0 temporary lighting system. Includes independent testing results, OSHA compliance documentation, and energy savings verification.

White Paper • 4 pages Download Whitepaper

Download the FLEX SLS Brochure

Complete technical specifications for the FM2A, FM10A, and FM30A modules, the FPS550 power supply, and the T-Connector / CDB1 accessory line.

Get the Brochure

Upgrade Your Construction Site Lighting

Ready to upgrade temporary lighting with a 27.5VDC low-voltage system that’s safer to install, faster to reconfigure, and reusable on the next project? Our team will spec the right FLEX SLS 3.0 configuration for your build.